<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-01 21-53-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -7 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 71 kHz 10036 24,8306
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,5 dBr 7,27 dBr 7,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 21:53, 1.03.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 71 kHz MIN: 16 kHz % above 75 kHz: 24,8306 Acquired: 2025/03/01 21:52:53 Total samples: 10036 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,8 dBr MIN: 6,5 dBr AVE: 7,27 dBr % above 10,0 dBr: 0,0 Last value: 7,8 dBr (2025/03/01 21:52:53) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 21:46 21:47 21:48 21:49 21:50 21:51 21:52 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality